5816
[NRS Function]
001 I/F Setting
002 CE Call
003 Function Flag
007 SSL Disable
008 RCG Connect T/O
009 RCG Write Timeout
SM Appendix
System Service Mode (F/SPF: D068/D069)
CTL
-
Selects the remote service setting.
[ 0 to 2 / 2 / 1 /step]
0: Remote service off
1: CSS remote service on
2: @Remote service on
Performs the CE Call at the start or end of the
service.
[0 or 1 / 0 / 1 /step]
0: Start of the service, 1: End of the service
This SP is activated only when SP
5816-001 is set to "2".
Enables or disables the remote service function.
[0 or 1 / 0 / 1 /step]
0: Disabled, 1: Enabled
Uses or does not use the RCG certification by SSL
when calling the RCG.
[0 or 1 / 0 / 1 /step]
0: Uses the RCG certification
1: Does no use the RCG certification
Specifies the connect timeout interval when calling
the RCG.
[1 to 90 / 10 / 1 second/step]
Specifies the write timeout interval when calling the
RCG.
[1 to 100 / 60 / 1 second/step]