System Service Mode (F/SPF: D068/D069)
SP5-XXX (Mode)
5001
All Indicators On
Turns on all LEDs. The LCDs turn on and off every 3 seconds. Press the
5001 1
reset key to end this program.
5024*
mm/inch Selection
Selects whether mm or inches are used in the display.
001
Europe/Asia model: [0: mm / 1: inch]
American model: [0: mm / 1: inch]
5045*
According Counter
5045 1 Counter Method
5055
Display IP address
001 Display IP address
D067/D068/D069/D072
After selecting the number, you must turn the main power switch off
and on.
CTL
Displays the number of the installed counter.
[0 to 2 / 0 / 1 /step]
0: 1 counter (Total)
1: 2 counters (Total and Prints)
2: 2 counters GPC
Displays or does not display the IP address
on the LCD.
[0 or 1 / 0 / -]
0: No (Not display), 1: Yes (Display)