Fusing Idling
1103*
Enables or disables the contact-release control. The following table lists the
results.
Setting
1103 1
C-R control
Idling time
Fusing quality
Fusing Temp Adj
1105*
Adjusts the target fusing temperature. Note that the thermistor is at the center
of the hot roller.
1105 1 Warm Up-Center
1105 3 Standby-Center
1105 5 Copying-Center
1105 7 Low Level 2-Center
1105 9 Thick-Center
1106
Display Fusing
1106 1 (Center and Leading edge) Displays the fusing temperature.
SM Appendix
System Service Mode (Basic: D067/D072)
[0 = No / 1 = Yes]
0 = No
Works
Shorter
Lower
[140 to 180 / 160 / 1°C/step]
[140 to 160 / 150 / 1°C/step]
[140 to 180 / 160 / 1°C/step]
[0 to 80 / 60 / 1°C/step]
[140 to 185 / 165 / 1°C/step]
5-143
1 = Yes
Does not work
Longer
Higher