Ricoh D072 Service Manual page 369

Hide thumbs Also See for D072:
Table of Contents

Advertisement

System Service Mode (F/SPF: D068/D069)
Instl: Condition
Displays a number that indicates the status of the @Remote service device.
0: Neither the registered device by the external RCG nor embedded RCG
device is set.
1: The embedded RCG device is being set. Only Box registration is
completed. In this status the this unit cannot answer a polling request from
201
the external RCG.
2: The embedded RCG device is set. In this status the external RCG unit
cannot answer a polling request.
3: The registered device by the external RCG is being set. In this status the
embedded RCG device cannot be set.
4: The registered module by the external RCG has not started.
Instl: ID#
202
Allows entry of the number of the request needed for the embedded RCG.
Instl: Reference
203
Executes the inquiry request to the @Remote GateWay URL.
Instl: Ref Rslt
Displays a number that indicates the result of the inquiry executed with
SP5816-203.
0: Succeeded
1: Inquiry number error
2: Registration in progress
204
3: Proxy error (proxy enabled)
4: Proxy error (proxy disabled)
5: Proxy error (Illegal user name or password)
6: Communication error
7: Certification update error
8: Other error
9: Inquiry executing
D067/D068/D069/D072
5-60
SM Appendix

Advertisement

Table of Contents
loading

This manual is also suitable for:

D067D069D068

Table of Contents