Ricoh D072 Service Manual page 368

Hide thumbs Also See for D072:
Table of Contents

Advertisement

Lmt Resend Cncl
Normally, it is best to allow unlimited time for certification and ID2 update
requests, and for the notification that the certification has been completed.
However, embedded RCG-M generates charges based on transmission time
174
for the customer, so a limit is placed upon the time allowed for these
transactions.
If these transactions cannot be completed within the allowed time, do this SP
to cancel the time restriction.
186 RCG-C M Debut Bit SW DFU
FAX TX Priority
This SP determines whether pushing the off-hook button will interrupt an
embedded RCG-M transmission in progress to open the line for fax
transaction. This SP can be used only if SP5816-164 is set to "0".
[0 or 1/ 0 / - ]
0: Disable. Setting the fax unit off-hook does not interrupt a fax transaction in
187
progress. If the off-hook button is pushed during a embedded RCG-M
transmission, the button must be pushed again to set the fax unit on-hook
after the embedded RCG-M transmission has completed.
1: Enable. When embedded RCG-M shares a line with a fax unit, setting the
fax unit off-hook will interrupt a embedded RCG-M transmission in progress
and open the line for a fax transaction.
Polling Man Exc
200
Executes the polling test.
SM Appendix
System Service Mode (F/SPF: D068/D069)
5-59