Code
Meaning
The line was disconnected
due to a timeout in V.34
0-81
phase 3 – equalizer
training.
The line was disconnected
due to a timeout in the V.34
0-82
phase 4 – control channel
start-up.
The line was disconnected
due to a timeout in the V.34
0-83
control channel restart
sequence.
The line was disconnected
due to abnormal signaling
0-84
in V.34 phase 4 – control
channel start-up.
The line was disconnected
due to abnormal signaling
0-85
in V.34 control channel
restart.
The line was disconnected
because the other terminal
requested a data rate
0-86
using MPh that was not
available in the currently
selected symbol rate.
SM Appendix
Suggested Cause/Action
The signal did not stop within 10 s.
Turn off the machine, then turn it back on.
If the same error is frequent, replace the FCU.
The signal did not stop within 10 s.
Turn off the machine, then turn it back on.
If the same error is frequent, replace the FCU.
The other terminal was incompatible.
Ask the other party to contact the
manufacturer.
6-9
Fax Error Codes
D067/D068/D069/D072