SC Tables (Basic: D067/D072)
No.
Definition
Communication Error between BICU and SBU
144
B
The BICU cannot correctly establish
communication with the SBU.
Automatic SBU adjustment error
The white levels of the white plate
and the white paper are
145
D
extraordinarily different during the
Scan Auto Adjustment (
SP4-428-001).
Image transfer error
Scanned images are not transferred
193
B
to the controller memory within one
minute.
Memory address error
The BICU does not receive the
198
B
memory address report from the
controller within one minute.
D067/D068/D069/D072
Symptom
3-38
Possible Cause
Loose connection of the flat
cable between the BICU and the
SBU
Defective flat cable between the
BICU and the SBU
Defective BICU
Defective SBU
Defective exposure lamp
Unclean white plate
Incorrect position or width of
white plate scanning (
SP4-015)
Defective BICU board
Defective SBU board
Defective BICU board
Defective controller board
Inconsistency between the
BICU firmware and the
controller firmware
Defective BICU
Defective controller
SM Appendix