Canon iR8500 Service Manual page 460

Hide thumbs Also See for iR8500:
Table of Contents

Advertisement

5) Put the developing assembly and the process unit back to their original positions.
6) Connect the connector [1] of the potential sensor.
7) Fit the potential sensor checking electrode (FY9-3041) [2] to the potential sensor [1].
When fitting the checking electrode to the potential sensor, take care so that
the magnet of the checking electrode will not come into contact with the
potential sensor cover.
COPYRIGHT© 2001 CANON INC.
F06-207-14
[2]
F06-207-15
2000 2000 2000 2000
CANON iR8500/7200 REV.1 AUG. 2001
CHAPTER 6 TROUBLESHOOTING
[1]
[1]
6-57