CHAPTER 2 NEW FUNCTIONS
d. Removing the Fixing/Feeder Unit Cover
1) Open the front cover, and shift down the
fixing/feeding lever to slide out the fix-
ing/feeding unit.
2) Remove the mounting screw [2] of the
releasing lever [1]; then, pushing the
releasing lever link [3] found at the rear
of the fixing/feeder unit, remove the re-
leasing lever while keeping it shifted
up.
3) Remove the mounting screw [1], and
detach the fixing knob [2].
4) Remove the mounting screw [3], and
detach the transfer separation charging
assembly cover [4].
5) Remove the 2 mounting screws [5], and
detach the fixing/feeder unit cover [6].