f. Mounting the Main Thermistor
When mounting the main thermistor to the fixing assembly, be sure that the tie-wrap [1] is
as shown.
The tie-wrap serves as a stopper by butting against the claw [2].
Check also to be sure that the main thermistor and the fixing roller are not away from
each other.
[2]
COPYRIGHT© 2001 CANON INC.
[1]
F02-909-11