CHAPTER 2 NEW FUNCTIONS
3) Remove the four screws [1], and detach
the reversal motor [2].
b. Removing the Lower Feed Motor
1) Remove the duplexing unit front cover
(four screws, three knobs).
2) Disconnect the connector [1], and re-
move the two screws [2]; then, detach
the lower feed motor [3].
2-144
COPYRIGHT© 2001 CANON INC.
[1]
F02-805-23
[2]
[3]
F02-805-24
2000 2000 2000 2000
CANON iR8500/7200 REV.1 AUG. 2001
[2]
[1]