Cw Adjustments (Uni-Directional) - MUTOH Rockhopper II series Maintenance Manual

Hide thumbs Also See for Rockhopper II series:
Table of Contents

Advertisement

5.5.6. CW adjustments (Uni-Directional)

To perform CW adjustments, please follow the steps mentioned below.
Step 1 :
Start the self-diagnostic function.
Notes :
Step 2 :
Select "Adj:Uni-D".
Step 3 :
Print a CW adjustment pattern.
Step 4 :
The odd rows (alternately 1A and 1B) are the references. So the even rows (2A, 2B, 3A, 3B, 4 A
and 4B) should be adjusted (use a magnifying with an enlargement of at least 10)
When you want to move the even rows (with dots) to the right, you have to increase (+) the value.
For example: The value is 20, adjust it to 30 for example
When you want to move the even rows (with dots) to the left, you have to decrease (-) the value.
For example: The value is 20, adjust it to 10 for example
1B
4B
Notes :
Notes :
Refer to "Self-Diagnosis Function".
The value is -20, adjust it to -10 for example
The value is -20, adjust it to -30 for example
1A
1B
4A
3B
For 87-inch specifications, the head 5-A, 5-B, 6-A, 6-B, 7-A, 7-B, 8-A, 8-B are
added.
In the event that all parts of unit do not line up due to part or assembly precision
error, make adjustments until everything in the area around center lines up in a
straight line.
Rockhopper II series printers – Maintenance Manual
1A
3A
165
1B
1A
2B
2A
AP-74065, Rev. 1.2, 27/09/04

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rockhopper ii 2hRockhopper ii 4h

Table of Contents