3.4. INSTALLATION

The Installation of the unit is explained below.

3.4.1. Conditions of the installation environment

Important :
Do not place the printer in following areas. Doing so may result in the printer
falling over and causing injury.
Unstable surfaces
Slanted place
Where vibration of other machines is transmitted.
Do not sit on the printer or put heavy things on the printer. Doing so may cause
the printer to fall and injure people.
Do not cover the ventilation hole of the printer with cloth, such as a blanket or
table cloth. Doing so could obstruct ventilation and cause fire.
Do not place the printer in humid and dusty areas. Doing so may result in
electrical shock or fire.
(1) Conditions of the installation environment
Select the place to install this unit according to the environmental condition in the table below.
Area
50" model
64" model
87" model
Floor loading capability
Electrical
Voltage
Frequency
Capacity
Environmental
Recommended
working environment
Operational conditions
Rate of change
Storage environment
Rockhopper II series printers – Maintenance Manual
11.7 m² or larger. Frontage of 4.3 m or greater.
12.7 m² or larger. Frontage of 4.7 m or greater.
14.3 m² or larger. Frontage of 5.3 m or greater.
2490Pa (300kg/m²) or over
AC100V - 120V or AC220V – 240V
50/60Hz±1Hz
AC100V - 120V: 3A or more
AC220V - 240V: 1.5A or more
Temperature: 25°C
Humidity: 40% to 60%, without condensation
Temperature: 18°C to 35°C
Humidity: 40% to 60%, without condensation
Temperature: No more than 2°C per hour
Humidity: No more than 5% per hour
Temperature: -20°C to 60°C
Humidity: 5% to 85%, without condensation (When ink has
been discharged.)