Head Rank Input Menu - MUTOH Rockhopper II series Maintenance Manual

Hide thumbs Also See for Rockhopper II series:
Table of Contents

Advertisement

5.5.2. Head rank input menu

Inputs the head rank.
The head rank is used to determine the operation voltage of the head and compensate the temperature.
Input head rank following the steps below.
(1) Selecting input method
When inputting head rank, select one of the following methods.
Input using the QR code
Input from the operation panel
(2) When input using the QR code has been selected
Make sure that the operation panel displays "Input HEAD1 QR code".
Input the QR code from the QR code reader.
* QRcode *
Input
Head1
Correctly entered : Initial charge menu
(3) When input from the operation panel is selected
Input the parameters of the upper and lower sections of the head rank using the operation panel keys.
* Panel *
ID1 - H
7BZ3E3CVXUWVWQQ 21 -
* Panel *
ID1 – L
00Y012VTTR 40UWJB -
Correctly entered : Initial charge menu
(4) Initial ink charge menu
When the input head rank has been confirmed, initial ink charge is performed.
QRcode
↓ ENTER
+
↓ ENTER
+
↓ ENTER
* Charge *
Ink charge
[enter]
↓ ENTER
* Charge *
[1]
No Catridge
↓ Set cartridge
* Charge *
Ink Charge
152
Rockhopper II series printers – Maintenance Manual
* QRcode *
Head ID input
Incorrectly entered : Error
Press "ENTER" to re-enter
* QRcode *
Head ID input
Incorrectly entered : Error
Press "ENTER" to re-enter
→ [CANCEL] Initial charge is not executed.
Voltage input value is updated.
AP-74065, Rev. 1.2, 27/09/04