Connecting The Phone Line To The Panel With A Db-8 Cord (49-442); Mounting/Connecting An Ac Power Transformer - Interlogix Advent Installation Instructions Manual

Commercial burglary and home navigator system
Hide thumbs Also See for Advent:
Table of Contents

Advertisement

5. If desired, add phone jack tamper by splicing the black
and yellow phone jack wires to the panel terminals and
adding a 2.0K ohm EOL resistor between the blue and
orange phone jack terminals as shown in Figure 21.
6. Check the phones on the premises for dial tone and the
ability to dial out and make phone calls. If phones do not
work correctly, check all wiring and correct where nec-
essary. Proceed to "Troubleshooting" on page 50 if
problems persist.
R J - 3 1 X
( C A - 3 8 A )
P H O N E J A C K
B R N
G R Y
B L U
O R G
Y E L
B L K
G R N
R E D
T E L C O
P R O T E C T O R
B L O C K
P H O N E
S P L I C E
( A )
( B )
W I R E
G R N
R E D
B L A C K
W H I T E O R Y E L L O W
G R N ( C )
R E D ( D )
Figure 21. Installing an RJ-31X Phone Jack
Connecting the Phone Line to the Panel
with a DB-8 Cord (49-442)
After installing the RJ-31X jack, you are ready to connect
the phone line to the panel.
To connect the DB-8 cord to the panel terminals and
RJ-31X jack:
1. Insert one end of the DB-8 cord plug into the RJ-31X
(see Figure 22).
2. Insert the other end of the DB-8 cord plug into the phone
jack on the Advent panel circuit board (see Figure 22).
Commercial Burglary and Home Navigator System
2 . 0 K O H M
E O L R E S I S T O R
4 9 - 4 6 7
( . O R
O P T I O N A L
J A C K
T A M P E R )
T O P A N E L T E R M I N A L 1 1
T O P A N E L T E R M I N A L 1 2
( O R T O A N Y G E N E R A L P U R P O S E
I / O T E R M I N A L P R O G R A M M E D A S A N
I N P U T . O R O P T I O N A L J A C K T A M P E R )
T O
P R E M I S E S
P H O N E S
8 5 4 3 G 1 0 A . D S .
3. Check the phones on the premises for dial tone and the
ability to dial out and make phone calls. If phones do not
work correctly, check all wiring and correct where nec-
essary. Proceed to "Troubleshooting" on page 50 if
problems persist.
(PANEL CIRCUIT BOARD)
PHONE JACK
Figure 22. Connecting the DB-8 Cord to the Panel and
RJ-31X Jack
Mounting/Connecting an AC Power
Transformer
Use the following AC power transformers with Advent pan-
els:
q 24 VAC output, 100 VA Class I, 110VAC, 60 Hz
(60-830).
q 24 VAC output, 100 VA Class II, 110VAC, 60 Hz
(60-823) Line Carrier AC Power Transformer.
1. Mount the transformer in the cabinet at one of the two
locations shown in Figure 5.
Note
Transformer load (secondary) terminals must face the
center of the enclosure.
2. Secure the transformer to the cabinet using the threaded
standoffs and supplied hex nuts.
3. Route the AC power transformer cord or wires through
one of the knockouts.
Note
The AC supply is non-power limited. It must be separated
from all power limited wiring in the cabinet by at least
0.25" and wired using a separate knockout.
4. Wire the AC power transformer to the panel as shown in
Figure 23.
Installing the System
DB-8 CORD
PLUG
BRN
GRY
RJ-31X
JACK
GRN
RED
8543268A.DSF
13

Advertisement

Table of Contents
loading