Interlogix Advent Installation Instructions Manual page 35

Commercial burglary and home navigator system
Hide thumbs Also See for Advent:
Table of Contents

Advertisement

List Zones
Default = NA
Use this item number to list information about existing zones. The
system will list the zone number, any zone text, zone type num-
ber, and the partition/area number.
To List Zones:
Once in program mode enter 47003. The display will show
nn,
,
nn,
ANY ZONE TEXT
TYPE
PARTITION
The panel will scroll through and display information about each
zone. To skip forward press #. To exit press *. Once the panel lists
all the zones it will return to the program menu.
Zone Attributes (Edit Zones)
Defaults = NA
Use this item number to edit the following zone attributes.
q
1—Critical Security Zone (Default = 0 [Off])
Enter 0 to turn attribute Off, 1 to turn attribute On. Critical
zones require special authority (partition master and full
authority codes) in order to be bypassed.
q
2—RF Supervisory Time (Default = A [4 hours - Commer-
cial Burg, 24 hours - Home Navigator])
Enter 0 for Supervisory Time A (17049), 1 for
Supervisory Time B (17050).
q
3—Zone Activity Threshold (Default = 0 [None])
Enter 0 for None, 1 for Threshold 1 (xx018), 2 for Threshold
2 (xx019), 3 for Threshold 3 (xx020).
q
4—Hardwire Smoke Verify (Default = 0 [Off])
Enter 0 to turn attribute Off, 1 to turn attribute On. If on,
when a hardwire smoke detector is tripped, the panel will
remove power for 5 seconds to reset the smoke. If a second
trip occurs within 60 seconds, an alarm will sound and a
report will be sent to the central station.
q
5—Delayed Zone (Default = 0 Off)
Enter 0 to turn attribute Off, 1 to turn attribute On. (see
17117).
q
6—Floor (Default = 0 [None])
Enter the floor number the zone resides on (1–90 above
ground, 91–99 below ground, 0 = None) (see 17074).
q
7—not supported.
q
8—not supported.
q
9—not supported.
q
10—Warning message index (Default = 0 [None])
Enter the desired warning message (1–5). If learned into
zone type 70 it will only play the desired warning message.
q
11—Zone Bypass Group (Default = 0 [None])
Enter the desired bypass group number (0–32). This will
allow users to directly bypass and unbypass groups of zones.
To Edit Zone Attributes:
1. Once in program mode enter 47004. The display shows
*
ZONE NUMBER OR PRESS
TO CANCEL
2. Enter the desired zone number and press #. The display shows
ENTER ATTRIBUTE NUMBER OR PRESS
3. Enter the attribute number from the list above and press #.
The display will show the current attribute setting. If desired,
change the attribute setting.
4. Press # to apply changes. To edit another attribute repeat step
1.
Commercial Burglary and Home Navigator System
47003
ZONE
/
n.
AREA
47004
ENTER
.
*
.
TO CANCEL
Test Buddies
Default = NA
Use this item number to test zone buddies.
To Test Buddies:
Once in program mode enter 47005. The display will show
. Once the test is complete the display will list buddies
TEST MODE
(see List Buddies 47006).
List Buddies
Default = NA
Use this item number to list information about existing buddy
zones. The system will list the buddy zone number, ID, and latest
buddy test results.
To List Buddies:
Once in program mode enter 47006. The display will list all four
buddies.
q
If the buddy doesn't exist, the panel will display
.
INVALID
q
If the buddy failed the latest test (47005), the panel will dis-
n
play
.
BUDDY
FAILED
q
If the buddy passed the latest test, the signal strength will be
displayed.
The panel will scroll through and display information about each
buddy. To skip forward press #. To exit press *. Once the panel
lists all the buddies it will return to the program menu.
Zone Delay Time
Default = 10 Seconds
Set the time delay (in seconds) between a zone being tripped and
the trip being processed by the panel. This allows time for a zone
to reset.
Note
This setting only applies to zones programmed as
delayed.
To Set Zone Delay Time:
1. Enter the item number.
2. Enter the delay time (1–255 seconds) and press #.
Programming the Panel
47005
BUDDY
47006
n
BUDDY
17117