No.
Name
Fire Supervisory A fire supervisory trouble has
96
been detected.
Note: Check marks (
* This type is not certified as a primary protection circuit for UL-listed systems and is for supplementary use only.
† Sounds instant police siren if two or more sensors are tripped within 4 minutes; otherwise sensors are followers to delayed
sensors. If central station Alarm Verification feature is on, type 18 functions like type 17.
‡ This type has not been investigated by UL.
§ Zone trip causes trouble, restoral causes trouble restoral.
Activity Levels as Follows:
Level #
Name
Level 1
OFF
PERIMETER/
Level 2
HOME
Level 3
FULL/AWAY
Level 4
NIGHT
Level 5
SILENT
\
Commercial Burglary and Home Navigator System
Table B1: Zone Type Characteristics (Continued)
Application
§
) represent characteristics present in a type.
The partition/area is disarmed. Only 24-hour sensors cause an alarm in the
OFF level. Cancelling alarms or entry delay automatically disarms to OFF.
The user is on-site and only requires perimeter protection. In addition to 24-
hour sensors, perimeter sensors such as those protecting exterior doors and
windows cause an alarm in the HOME/PERIMETER level.
The user is away and requires complete protection. 24-hour sensors, perimeter
sensors, and interior sensors cause an alarm in the AWAY/FULL level.
The user is on-site and perimeter and 24-hour sensors are active. Since users
are not moving around, Interior sensors except those in night groups are also
active.
Same as Level 3, but police intrusion alarms are silent.
1, 2, 3, 4,
Aux./Aux.
Instant
5
Description
Appendix B: Reference Tables
Attributes
- Open
- Entry, but no exit delay
- Cannot be disabled
- Closed
- Entry and exit delay
- Can be disabled
Same as Level 2.
Same as Level 2.
Same as Level 2.
83