Interlogix Advent Installation Instructions Manual page 20

Commercial burglary and home navigator system
Hide thumbs Also See for Advent:
Table of Contents

Advertisement

Programming the Panel
Keypad Tamper
Default = 0 (Off)
This setting enables keypad tamper. When on, the panel will gen-
erate a police alarm when it detects four or more incorrect access
code entry attempts that do not include a valid access code. A
tamper report is also sent to the central station.
Turning the Keypad Tamper Setting On/Off:
Once the item number has been entered, enter 1 for on (generate
alarm and report) or 0 for off. Press # to apply the new setting.
No Activity Internal
Default = 0 (Not Active)
This setting allows you to select the length of time (in hours) the
panel will wait after not detecting any activity before initiating a
no-activity pre-alarm. Once a no-activity pre-alarm is initiated the
panel will wait until the time in the No Activity Report Delay set-
ting (xx010) expires before generating an alarm.
Setting the No Activity Internal Time:
1. Once the item number has been entered, enter the number of
hours (1–24) you wish the panel to wait before initiating a no-
activity pre-alarm, or 0 for not active.
2. Press # to apply the new setting.
No Activity Report Delay
Default = 5 Minutes
This setting allows you to select the length of time (in minutes)
allowed after the No Activity Tripped setting (xx009) time has
expired. If no activity is detected during this time the panel sends
a report to the central station. If the user(s) generate activity
within this delay period no report will be sent.
Setting the No Activity Report Time:
Once the item number has been entered, enter the number of min-
utes (1–10) you wish the panel to wait before sending a report.
Press # to apply the new setting.
Note
If the No Activity Tripped After setting (xx009) is set to 0
(not active) this setting will have no affect.
Generate Alarm for Suspicion Trips
Default = 1 (On)
This setting allows you to enable the panel to generate a suspicion
trip alarm. If on, and suspicion zones are tripped, an alarm will be
generated after the Suspicion Alarm Delay (xx015) expires. If off,
the tripping of suspicion zones will not generate an alarm.
To Turn Generate Alarm for Suspicion Trips On/Off:
Once the item number has been entered, enter 1 for on or 0 for off.
Press # to apply the new setting.
18
xx076
Suspicion Alarm Delay
Default = 05 Minutes
Select the length of time in minutes in which an alarm can be
avoided after a suspicion zone is tripped. This allows the user
time to prevent a false alarm from being generated.
Programming the Suspicion Alarm Delay:
Once the item number has been entered, enter the number of min-
utes (1–15) you wish the panel to wait before going into alarm.
Press # to apply the new setting.
Note
If the Generate Alarm Suspicion Trips setting (xx078) is
set to off, this setting will have no effect.
xx009
First Trip Local Second Trip Report
Default = 0 (Off)
If on, the first zone trip in a two trip zone type (18 or 77) causes a
local police alarm. A second zone trip from a different zone,
occurring within four minutes of the first zone trip, generates a
report. Zones must reside in the same partition/area. If off, the
first zone trip starts a timer and the second zone trip causes the
alarm and report.
To Turn This Setting On/Off:
Once the item number has been entered, enter 1 for on or 0 for off.
Press # to apply the new setting.
xx010
X-10 and Non-X-10 Output Settings
X-10 House Code 1
Default = Partition/Area Number
The house code is a number from 1 to 16 (representing A–P) used
to communicate panel signals to line carrier devices such as X-10
Lamp, Appliance, and Universal Modules. You can have up to
two house codes per partition/area.
Enter the panel house code setting used for the first 16 X-10 line
carrier devices. The system commands "All Lights On/Off" or
"All Units On/Off" control only modules with House Code 1
(within respective partition/area). See Table B4 and B5 on
page 90 for information on defaults.
Entering House Code 1:
Once the item number has been entered, enter the desired house
code (1–16). Press # to apply the new setting.
xx078
X-10 House Code 2
Default = Partition/Area Number + 8
Enter the panel house code setting used for the last 16 X-10 line
carrier devices within respective partition/area. See Table B4 and
B5 on page 91 for information on defaults.
Entering House Code 2:
Once the item number has been entered, enter the desired house
code (1–16). Press # to apply the new setting.
Commercial Burglary and Home Navigator System
xx015
xx080
xx022
xx023

Advertisement

Table of Contents
loading