Special Installation Requirements
q A SuperBus 2000 Dual Phone Line Module (60-768) for
expansion to primary and secondary phone line report-
ing.
System Setup and Programming
The system Feature Numbers shall be set as follows in UL
609 listed systems:
Table 2: UL 609 Listed System Settings
Feature No.
Feature
xx002
Siren Sound Time
yy004
Communication Format
xx088
Report Partition/Area Events
xx092
Auto Forced Arming
xx097
Exterior Siren Arming Verifi-
cation
xx102
Exit Delay Reset
17034
Auto Phone Test Frequency
17036
AC Stable Time
17041
AC Report Delay
17049
RF Supervisory Time
17069
No Phone Line
17072
Enable RF Jam Detect
17073
Automatic Panel Backup Bat-
tery Test Interval
17076
Commercial/Residential
17078
Detect RF Receiver Failure
17079
Alarm Messages Played at
High Volume
17096
Report System Events
47004
#2-Supervisory Time Zone
Attribute (all zones)
#4-Hardwire Smoke Verify
Zone Attribute
xx = Two digit partition number.
yy = Two digit non-pager phone number.
Household Fire Warning System Units (UL 985)
Basic system, plus:
q Hardwire Smoke Detector (Compatibility Identifier
60-562, 20 per loop maximum):
q System Sensor models 2100S, 2100TS, 2100D,
2100TD, 2400, or 2400TH added (learned) into Zone
Type 80.
q Sentrol models 429AT, 521B, or 521BXT added
(learned) into Zone Type 80.
The basic system may also include:
q SuperBus 2000 Commercial RF Transceiver (60-821)
for use with listed wireless signaling devices.
q Wireless Smoke Sensor (60-506-319.5 or 60-848-95)
added (learned into Zone Type 80.
q SuperBus 2000 Printer or Automation Module
(60-783) for use with a listed printer.
2
q SuperBus 2000 Dual Phone Line Module (60-768) for
expansion to primary and secondary phone line report-
ing.
System Setup and Programming
The system Feature Numbers shall be set as follows in
UL 985 listed systems:
Required Setting
Feature No.
16 min. minimum
xx002
0 Contact ID
xx003
1-On
xx004
0-Off
yy004
0-Off
xx085
xx086
0-Off
1 Day
xx087
90 sec. maximum
xx088
6-12 hours
xx092
4 hours
xx097
0-Off
xx102
1-On
xx108
1=4 hours
17036
1-Commercial
17041
1-On
17049
1-On (High)
17069
1-On
17072
Set to 4 hrs
17073
0-Off
17076
17078
17079
17096
47004
xx = Two digit partition number.
yy = Two digit non-pager phone number.
Household Burglar-Alarm System Units (UL 1023)
Basic system plus:
q Hardwire Magnetic Contact (13-068 or 13-071)
The basic system may also include:
q SuperBus 2000 Commercial RF Transceiver (60-821)
for use with listed wireless signaling devices.
q Wireless Learn Mode Door/Window Sensor (60-362)
q SuperBus 2000 Printer or Automation Module
Table 3: UL 985 Listed System Settings
Feature
Siren Sound Time
Entry Delay
Exit Delay
Communication Format
Enable Police Panic Keys
Enable Auxiliary Medical
Panic Keys
Enable Fire Panic Keys
Report Partition/Area Events
Auto Forced Arming
Exterior Siren Arming Verifi-
cation required
Exit Delay Reset
Local Trouble Annunciation at
LTIME.
AC Stable Time
AC Report Delay
RF Supervisory Time
No Phone Line
Enable RF Jam Detect
Automatic Panel Backup Bat-
tery Test Interval
Commercial/Residential
Detect RF Receiver Failure
Alarm Messages Play at High
Volume
Report System Events
#2-Supervisory Time Zone
Attribute (all zones)
#4-Hardwire Smoke Verify
Zone Attribute
Commercial Burglary and Home Navigator System
Required Setting
4 min. minimum
45 sec. maximum
60 sec. maximum
0 Contact ID
1-On
1-On
1-On
1-On
0-Off
0-Off
0-Off
1-On
90 sec. maximum
6-12 hours
4 hours
0-Off
1-On
1-4 hours
0-Off Residential
1-On
1-On High
1-On
A (set to 4 hrs. in
Feature 17049)
0-Of

Advertisement

Table of Contents
loading

Table of Contents