Feature
Problem
X-10 Lamp/Appliance Modules
Lights or devices controlled by the X-10 Modules are not working.
Zones, Loops
(See Hardwire Inputs, Sensors.)
Commercial Burglary and Home Navigator System
1. Check that the light or device is working and the power switch is on.
2. Confirm light or device operation at working outlet.
3. Check that the lights or devices are plugged into X-10 Modules and that the X-10 Modules are
plugged into outlets that are not controlled by a switch. If necessary, relocate modules to non-
switched outlets.
4. Check that the HOUSE dial on the X-10 Modules match the house code programmed into the
panel.
5. Check for correct X-10 module unit settings and panel programming.