Recovery Guru - Recover From Failure - IBM System Storage DS3500 Introduction And Implementation Manual

Table of Contents

Advertisement

Draft Document for Review March 28, 2011 12:24 pm
Figure 14-124 Prepare for removal
2. In this window, you select the Enclosure and then the Component within that enclosure
from the two drop-down menus. Then click the Prepare for Removal button.

14.13 Recovery Guru - Recover from Failure

The Recovery Guru is a component of the DS Storage Manager (Subsystem Management
Window) (SMW) that diagnoses storage subsystem problems and recommends recovery
procedures to fix those problems. Problems in the storage subsystem are indicated as
follows:
A Needs Attention storage subsystem icon appears within the following elements of the
storage management software:
– In the Status column on the Devices tab in the Enterprise Management Window.
– In the Storage Subsystem Status area below the menu bar in the SMW
– In the title bar of the SMW
– In the Status portlet on the Summary tab in the SMW
The Recovery Guru Optimal toolbar button in the SMW changes to a blinking Recovery
Guru Needs Attention toolbar button.
Non-Optimal component icons appear on the Logical tab and the Physical tab of the SMW.
Critical Simple Network Mail Protocol (SNMP) notifications or e-mail error messages are
sent.
The fault LEDs on the hardware come on.
The Recover from Failure link appears in the DS Storage Manager (Subsystem
Management) Support tab, as shown in Figure 14-125 on page 420.
7914support2-0209.fm
Chapter 14. Administration - Support
419

Advertisement

Table of Contents
loading

Table of Contents