To update the connectivity-module firmware to the latest version, complete the following
steps:
1. Log on to the SAS Connectivity Module using the Web interface with the IP address
defined for the connectivity module in the BladeCenter Advance Management Module
(AMM), as shown in Figure 18-8. Use USERID as the user Id and PASSW0RD as the
password. You can change the password under the Administer Users menu option once
you are logged on.
Figure 18-8 SAS Connectivity Module - Login
2. In the Monitor Module window, click Update Firmware. The Update Firmware window
opens, as shown in Figure 18-9 on page 561. The current firmware level is also displayed.