VeriFone Omni 3200 Reference Manual page 71

Hide thumbs Also See for Omni 3200:
Table of Contents

Advertisement

Table 17 Initiate Destructive Memory Test
Display
3. MEMORY TEST
(or)
MEMORY -OK-
(or)
MEMORY ERROR
4. SYSTEM= (Firmware ID)
[BACKSPACE]: Initiate Destructive Memory Test
Performing System Mode Operations
The memory test runs continuously until you stop the
test (see below).
During the test, the message displayed on the terminal
screen alternates between MEMORY TEST and
MEMORY -OK-.
The message MEMORY -OK- indicates that no
memory problems were detected during the previous
test.
NOTE: If a problem is detected during the test, the
error message ***BAD RAM*** is displayed. If you
see this message, contact your local VeriFone
representative for assistance.
To stop the test, press any key while the MEMORY
-OK- message is displayed. The message MEMORY
ERROR is then displayed to indicate that the contents
of the memory were erased during the test.
Press [CLEAR] to return to the System Prompt.
Because contents of the Omni 3200 application
memory (SRAM) were cleared during the test, you can
now proceed to select the appropriate System Mode
function and download a new application program.
NOTE: For more information about application
downloads, please refer to the section "Performing
Downloads."
Action