Terminate Diagnostics And Restart Terminal; [Space] - Single Step Through Program (Debugger Only) - VeriFone Omni 3200 Reference Manual

Hide thumbs Also See for Omni 3200:
Table of Contents

Advertisement

X — Terminate Diagnostics and Restart Terminal
[space] — Single Step through Program (Debugger Only)
Descriptions of Diagnostic and Debugging Commands
The X command stops executing the application program and restarts
the terminal. If the terminal is running remote diagnostics in the
System Mode, the command will make the terminal exit the System
Mode and restart itself.
This command is typically used for disconnecting the phone line link
with the remote computer.
The terminal sends the response packet to the diagnostic computer to
indicate that it has received the command.
Command Packet Received by Terminal:
<FFh> <55h> <count> X <CRC1> <CRC2>
Response Packet Sent by Terminal:
<FFh> <55h> <count> X <CRC1> <CRC2>
This command stops the execution of the application and single-steps
either a line of the source code or an EM instruction, depending on
bit 7 used in the configuration 'T' command. The terminal also sends
a response packet. The execution can be resumed at any time with the
resume 'R' command.
Command Packet Received by Terminal:
<FFh> <55h> <count> <space character> <CRC1> <CRC2>
Response Packet Sent by Terminal:
<FFh> <55h> <count> <space character> <CRC1> <CRC2>
Remote Diagnostics and Debugging