Alarm Clock – System (System Reminder)
The DX-80 system may be set to alert all Digital Extensions at predetermined intervals during the day. Eight (8)
intervals are available for predetermined operation. The "Play Time" is also predetermined and set in the system
programming. Play Time dictates how long the music source will be played over the digital extensions (the time
period is adjustable from 1 to 10 minutes). The music source connected to the "MC1" music connector is used for the
System Reminder (unless the internal music source is selected by option strap on the CPM--see Installation).
Related Features
MC1 Music Source
Related Programming
System Application - System Time, (PC-DBA: ALT-T)
System Resource - System Reminder
Operation
No user operation is required. When the programmed time interval(s) are reached, the internal music source
or MC1 music source is heard over all digital extensions for the duration of the "Play Time."
Conditions
a)
A System Reminder in progress is canceled at an extension when another function is invoked.
b)
The music source connected to the MC1 music input is used for the System Reminder.
c)
Extensions monitoring Background Music channel MC1 will not recognize the System Reminder.
d)
The music alarm will not play at an extension that is busy on a call (handset or speakerphone), or in Do Not
Disturb (DND) mode.
Default Setting
No System Reminder times are set for any system Tenant Group.
Alarm Play Time is set at one (1) minute.
Programming Abstract
Set the system time and date to the correct local time and date.
Set the System Reminder Time(s) for the appropriate time and for each Tenant Group.
Programming via the DET (Digital Extension Terminal)
back
next
Note: [
], [
], [
three buttons below the LCD display to actuate the associated operation.
Enter Database Administration using the feature code
########
"
show
Press [
]. The DB Item Select screen displays.
Input 03-19.
save
Press [
]. The database item "ALARM PLAY" displays.
chg
Press [
] (change) until the appropriate Alarm Play Time displays (in seconds.)
back
Press [
] or [
Programming via PC-DBA
Note: PC-DBA is a DOS-based programming utility.
Enter PC-DBA by typing "DX-80" at the DOS prompt in the PC-DBA working directory and then pressing «.
The program title page displays.
Press any key at the program title page to enter the Main Menu.
P7290 IMM
DX-80 I
NSTALLATION AND
show
chg
bksp
], [
], [
], and [
." (Note: This eight-character password can be changed.)
next
] to continue programming. Or exit programming.