Background Music (Bgm); Barge-In (Intrusion); Battery Backup (Memory) - Comdial DX-80 Installation & Maintenance Manual

Digital hybrid key telephone system
Table of Contents

Advertisement

Programming Abstract
No database programming is required.
Call Forward Lamp indication may be eliminated via Attendant Administration if necessary.

Background Music (BGM)

The DX-80 system has two (2) standard external music source inputs for Music On Hold and Background Music.
When a Digital telephone is idle and this feature is activated, you can monitor background music (BGM) through the
telephone speaker. You can use the feature code or press the programmed feature button to select BGM Channel 1
(771), BGM Channel 2 (772).
This is a standard feature of the system , no additional equipment is required other than your choice of Music sources.
Related Features
Music on Hold
Related Programming
System Application – Music Source Length
System Application – Music Source Leading 1, 2 & 3
Conditions
a)
One feature button is already setup for BGM operation at the factory.
b)
The feature button LED will not light when BGM is activated.
c)
BGM automatically turns off when you receive or make a call.
d)
BGM turns on again when the telephone return to idle status.
Default Settings
System Application – Music Source Length set at "3." (Range is 1-4.)
System Application – Music Source Leading 1 set at "771." (Range is any available digits.)
System Application – Music Source Leading 2 set at "772." (Range is any available digits.)
Programming Abstract
Make changes as required to music channel numbering. See Flexible Number Plan for information on
specific programming details.

Barge-In (Intrusion)

See Intrusion – Extension

Battery Backup (Memory)

The DX-80 system is equipped with a Lithium Ion battery for maintaining volatile system database programming and
extension programming during commercial AC power interruption. The memory backup will maintain the database
programming, time and date displays, personal speed dial numbers, feature button programming, etc., for up to
seven (120) days of continuous AC power loss. When system AC power is restored, the system will resume normal
operation.
During AC power interruption, the system will not operate unless System Battery Back-Up via a UPS is equipped.
When the "Cold Start/Normal" option strap on the CPM Module is operated to the "Cold Start" position, with the KSU
AC power turned off, the memory backup battery is removed from the volatile memory circuit. This option strap
condition is used only to initialize the system database and restore all programmable data to the factory configured
default program.
P7290 IMM
DX-80 I
M
NSTALLATION AND
AINTENANCE
3-31
M
03/01
ANUAL
771/772
Alarm Clock - System

Advertisement

Table of Contents
loading

Table of Contents