Mute - Comdial DX-80 Installation & Maintenance Manual

Digital hybrid key telephone system
Table of Contents

Advertisement

Press
to return to the previous menu level or press
screen or exit programming.
Programming via PC-DBA
Note: PC-DBA is a DOS-based programming utility.
Enter PC-DBA by typing "DX-80" at the DOS prompt in the PC-DBA working directory and then pressing «.
Press any key at the program title page (as it requests) to enter the Main Menu.
Select PC-DBA from the main menu.
Select Programming from the PC-DBA menu. Then press «.
Use ¢£¤¥ to highlight "CO Line" and then press «.
Use ¢£¤¥ to highlight "Category 2" and then press «.
Use ¢£¤¥ to highlight the database item "MOH Source" for the CO Line to be changed.
Press «
.
Each time that enter is pressed the value of this database item is updated.
Continue making other programming changes as required.
When all changes are made press the ° (escape) key to exit this database-programming screen. You will
see the prompt: "Exit This Feature"; press "Y" for yes.
You will then be prompted to "Save Current Setting?"
Press "N" to abort changes and leave all data unchanged.
Press "Y" to save changes.
If you press "Y" (yes), you will then be prompted "File Exists, Override?"
Press "N" to abort changes and leave all data unchanged.
Press "Y" (yes) to continue with the save operation.
Press ° (escape) again to return to the Database Programming menu.
Continue making other programming changes or exit PC-DBA programming.
Note: Changes made via PC-DBA are not updated to the DX-80 system memory until a "SEND" function
has been performed. Please refer to the Programming section of this manual to learn more about this
procedure.

Mute

Mute is provided to allow for temporary canceling of transmission to the connected party. Whenever a private
conversation is required inside the office, Mute can be invoked to prohibit the telephone-connected party from
listening in. Press the Mute button during a conversation to cancel the microphone whenever necessary.
All Digital Speakerphones have a standard mute button.
Operation
1.
While connected to any call, press the
2.
Press
again to cancel. The display momentarily shows:
Conditions
When MUTE is active, the red Auxiliary Lamp flashes slowly.
P7290 IMM
DX-80 I
M
NSTALLATION AND
AINTENANCE
button. The display momentarily shows:
MUTE ACTIVE
MUTE INACTIVE
3-175
M
03/01
ANUAL
to return to the DB Item Selection