Specifications; Current Draw - Comdial DX-80 Installation & Maintenance Manual

Digital hybrid key telephone system
Table of Contents

Advertisement

Specifications

Current draw:

Use this chart to calculate the Amphour requirements of the DX-80 system based upon its configuration.
This information is typically used to apply UPS battery requirements.
Component
KSU1 (7201)
KSU2 (7202)
COM4 (7210)
DPM8 (7220)
APM4 (7230)
MDM (7249)
AAM (7240)
PC-8 (7243)
FL-4 (7241)
FL3HR (7241E)
DET (7260-00)
DSS (7266-00)
Station wire:
per DET, DSS and
IST
Multiply the unit times the quantity installed in the subject
application (site) and add the right column for the total
current draw (Amps) @ 117VAC for this site.................
P7290 IMM
DX-80 I
M
NSTALLATION AND
AINTENANCE
Current Draw
(Amps)
@ 117 VAC
0.18A
0.17A
0.02A
0.01A
0.08A
0.01A
0.01A
0.15A
0.02A
0.01A
0.016A
0.016A
0.02A every 100 ft. of
24AWG
1-14
M
03/01
ANUAL
Extended
Quantity
Total Amps
1
0.18A
1 max.
2 max.
4 max
3 max.
1 max.
1 max.
1 max.
1 max.
1 max.
48 max.
12 max.
?

Advertisement