Power Supply

The power supply circuitry of the DX-80 incorporates a linear design AC transformer with a choice of input
voltage taps. The transformer primary windings are shipped wired for 117vac applications. A factory
insulated tap wire may alternately be connected for 230vac applications. Since the power supply is linear in
design the output voltage varies between 21.6vdc and 32vdc depending on load and stability of the input
voltage. The output voltage is delivered to the 408M (in KSU1, 408E in KSU2) for voltage regulation. All
system operation and logic voltages are produced at the 408M/E.
Two fuses are equipped on the power supply board, one for ac input over-voltage protection and one for DC
output over-current protection. A main power switch is accessible when the KSU cover is in place. In the
event battery backup operation is desired the KSU power cord can be connected to a external (ancillary)
UPS (Un-interruptible Power Supply). It is the responsibility of the installer to match the battery
requirements/UPS requirement to the specific needs of the equipment owner.
To determine the battery requirement needs and UPS requirement use the chart in Specifications (this
section) to find the current draw and necessary Amp/Hour back up support that the battery/UPS is to supply.