Current draw:

Use this chart to calculate the Amphour requirements of the DX-80 system based upon its configuration.
This information is typically used to apply UPS battery requirements.
Component
KSU1 (7201)
KSU2 (7202)
COM4 (7210)
DPM8 (7220)
APM4 (7230)
MDM (7249)
AAM (7240)
PC-8 (7243)
FL-4 (7241)
FL3HR (7241E)
DET (7260-00)
DSS (7266-00)
Station wire:
per DET, DSS, and IST
Multiply the unit times the quantity installed in the subject application (site) and
add the right column for the total current draw (Amps) @ 117VAC for this
site......
P7290 IMM
DX-80 I
M
NSTALLATION AND
Current Draw
(Amps)
@ 117 VAC
0.18A
0.17A
0.02A
0.01A
0.08A
0.01A
0.01A
0.015A
0.02A
0.01A
0.016A
0.016A
0.02A every 100 ft. of
24AWG
1-14
M
AINTENANCE
ANUAL
Quantity
1
1 max.
2 max.
4 max.
3 max.
1 max.
1 max.
1 max.
1 max.
1 max.
48 max.
12 max.
?
Extended
Total Amps
0.18A