Fujitsu PRIMEQUEST 1000 Series Tool Reference page 345

Hide thumbs Also See for PRIMEQUEST 1000 Series:
Table of Contents

Advertisement

PRIMEQUEST 1000 Series Tool Reference
CHAPTER 3 PSA Web-UI (Web User Interface) Operations
Button
Select All
Release All
Return
(1) Menu operations
[Partition] - [Partition#x] - [PSA] - [PCI Devices] - [Unit]
(2) Window operations
- Clearing the Fibre Channel hardware status
1. Check the check box in [Status] of [PCI Device Information]. Then, click the [Status Clear] button.
(See the remarks below.)
A settings confirmation dialog box appears.
2. Click the [OK] button in the settings confirmation dialog box.
This clears the Fibre Channel hardware status.
3. Click the [Return] button.
The browser returns to the [PCI Devices] window.
- Proceeding without clearing the status of the Fibre Channel
1. Check the check box in [Status] in [Information about devices connected to controller]. Then, click
the [Status Clear] button. (See the remarks below.)
A settings confirmation dialog box appears.
2. Click the [OK] button in the settings confirmation dialog box.
This clears the hardware status of each device connected to the Fibre Channel.
3. Click the [Return] button.
The browser returns to the [PCI Devices] window.
- Proceeding without clearing the status of the storage controller
1. Click the [Return] button.
The browser returns to the [PCI Devices] window.
Remarks
- Clicking the [Select All] button checks all the check boxes. Clicking the [Release All] button unchecks all
the check boxes.
- You can clear the status of up to 500 units at one time. If you click the [Status Clear] button with more than
500 units selected, a confirmation dialog box appears. The dialog box asks whether you want to clear the
status of the first 500 units.
(3) Error message
suppression of e-mail, REMCS, or SNMP trap notification by a notification
suppression function.
The window displays the [Select All] button only for users who have setting
privileges.
Clicking the [Select All] button checks all the check boxes.
The window displays the [Release All] button only for users who have setting
privileges.
Clicking the [Release All] button unchecks all the check boxes.
Click the [Return] button to return to the [PCI Devices] window.
313
Description
C122-E110-10EN

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Primequest 1800e2Primequest 1800e

Table of Contents