PRIMEQUEST 1000 Series Tool Reference
CHAPTER 3 PSA Web-UI (Web User Interface) Operations
Item
Total Packets
Displays the total number of IP datagrams received from all other stations. Error datagrams
are also counted.
Total Bytes
Displays the number of received bytes.
FCS Errors
Displays the number of packets containing an error detected during the FCS test. The
cause is poor transmission quality.
Alignment Errors
Displays the number of packets that were received by the selected interface but had an
invalid length because the number of bytes was not a whole number. The cause is poor
transmission quality.
Frame Too Long
Displays the number of packets that were received by the selected interface and were
longer than the permitted maximum packet length (1,518 bytes).
MAC Receive Errors Displays the number of packets that were not received successfully because of a MAC
layer internal error.

TABLE 3.12 Buttons in the [Ethernet Controller] window

Button
Status Clear
The window displays the [Status Clear] button only for users who have setting privileges.
Check the check box in [Status] in [PCI Device Information]. Then, click the [Status Clear]
button. A settings confirmation dialog box appears. Click the [OK] button in the settings
confirmation dialog box to clear the status of the Ethernet controller.
Clicking the button also releases any suppression of e-mail, REMCS, or SNMP trap
notification by a notification suppression function.
Return
Click the [Return] button to return to the previous window.
(1) Menu operations
[Partition] - [Partition#x] - [PSA] - [PCI Devices] - [Unit]
[Partition] - [Partition#x] - [PSA] - [Network] - [IPv4 Interfaces] - [Unit]
[Partition] - [Partition#x] - [PSA] - [Network] - [IPv6 Interfaces] - [Unit]
(2) Window operations
- Clearing the status of the Ethernet controller
1. Check the check box in the [Status] field. Then, click the [Status Clear] button.
A settings confirmation dialog box appears.
2. Click the [OK] button in the settings confirmation dialog box.
This clears the status of the Ethernet controller.
3. Click the [Return] button.
The browser returns to the previous window.
- Proceeding without clearing the status of the Ethernet controller
1. Click the [Return] button.
The browser returns to the previous window.
Description
Description
302
C122-E110-10EN