Jog Frequency Operation Without Forward And Reverse Commands (Fjog/Rjog) - Omron SYSDRIVE RV Series User Manual

High-function general-purpose inverters
Table of Contents

Advertisement

Jog Frequency Operation without Forward and Reverse Commands
(FJOG/RJOG)
The FJOG/RJOG command functions operate the Inverter using jog frequencies by using the terminal ON/
OFF operation. When using the FJOG/RJOG commands, there is no need to input the Run Command.
To use this function, set one of the parameters H1-01 to H1-06 (multi-function contact input terminal S3 to S8
function selection) to 12 (FJOG command) or 13 (RJOG command).
Related Parameters
Param-
eter
Number
Jog
frequency
reference
d1-17
Jog
Reference
* 1. The upper limit of the setting range depends on the upper limit set in E1-04.
* 2. When C6-01 = 1, the upper limit is 400.00.
Multi-Function Contact Inputs (H1-01 to H1-06)
Setting
Value
12
FJOG command (ON: Forward run at jog frequency d1-17)
13
RJOG command (ON: Reverse run at jog frequency d1-17)
Application Precautions
Jog frequencies using FJOG and RJOG commands are given priority over other frequency references.
When both FJOG command and RJOG commands are ON for 500 ms or longer at the same time, the
Inverter stops according to the setting in b1-03 (stopping method selection).
-90
6
Name
Description
Display
The frequency reference
when the jog frequency ref-
erence selection, FJOG com-
mand, or RJOG command is
ON.
Change
Setting
Factory
during
Range
Setting
Opera-
tion
0.00 to
6.00
Yes
300.00
Hz
*1 *2
Function
Control Methods
Regis-
V/f
Open
Flux
ter
V/f
with
Loop
Vec-
PG
Vector
tor
Q
Q
Q
Q
292H
Control Methods
Open
V/f
Flux
Loop
V/f
with
Vec-
Vec-
PG
tor
tor
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes