Basic Operation

5-3 Setting the Local/Remote Mode

The 3G3JV operates in local or remote mode. The following description
provides information on these modes and how to select them.
Basic Concept
Operation mode
Local
The Inverter in a system
operates independently in
this mode so that the
Inverter can be checked
independently.
Remote
The Inverter in a system
operates according to the
control signal of the host
controller.
Local/Remote Selection Methods
The following two selection methods are available to set the Inverter to local or remote
mode.
Select the mode with the LO/RE Key of the Digital Operator.
Set any one of multi-function inputs 1 through 4 (n36 through n39) to 17 to set the
Inverter to local mode with control input turned ON.
Note If the above setting is made, mode selection with multi-function input will be pos-
sible, but not with the Digital Operator.
5-6
Basic concept
Description
Operation Command
Starts with the RUN Key of the Digital
Operator and stops with the
STOP/RESET Key.
Frequency Reference
Set with the Digital Operator or the FREQ
adjuster.
Set with frequency reference selection in
local mode in n07.
Operation Command
Selectable from two types and set in n02.
Frequency Reference
Selectable from five types and set in n03.