ProSafe® Gigabit L3 Managed Stackable Switches Software Administration Manual
10.
Use Adv Interval to specify the maximum time allowed between sending router
advertisements from the interface. Default value is 600. Range of maximum advertisement
interval is 4 to 1800.
11.
Use Adv Managed Config Flag to specify the router advertisement managed address
configuration flag. When true, end nodes use DHCPV6. When false, end nodes auto
configure addresses. Default value of managed flag is disable.
12.
Use Adv Other Config Flag To specify router advertisement for "other" Stateful
configuration flag. Default value of other config flag is disable.
13.
Use Adv Suppress Flag to specify router advertisement suppression on an interface.
Default value of suppress flag is disable.
14.
Use Destination Unreachables to specify the Mode of Sending ICMPv6 Destination
Unreachables on this interface. If Disabled then this interface will not send ICMPv6
Destination Unreachables. By default IPv6 Destination Unreachables mode is enable.
Table 14.
Field
Operational Mode
236 |
Chapter 4. Routing
Description
Specifies operational state of an interface. Default
value is disable.