2 Ensure that IP is routable.
3 Enable the Bootp check box on the PXE device subnet/VLAN.
4 Select the interface that the PXE devices are connected to.
5 Edit the circuit.
6 Click Protocols.
7 Click Add/Delete.
8 Ensure that there is a check mark in the Bootp check box.
9 Click OK.
10 Click Protocols > IP > Bootp > Relay Agent interface table.
The interface where Bootp was enabled is visible in the list.
11 Click Preferred server.
12 Change the Pass through mode value to Bootp and DHCP.
13 Set up the relay agents:
13a Click Add.
13b In the Relay agent IP address box, type the local LAN IP address.
13c In the Target server IP address box, type the DHCP server IP address.
13d Click OK.
13e Change the Pass through mode value to Bootp and DHCP.
13f Perform
13g Apply the configuration.
Configuring Bay Network Equipment
Perform the following steps on the switch:
1 Enable DHCP for the client VLAN using the following command lines:
# config vlan1 ip
# dhcp enable
2 Configure IP helpers to forward DHCP requests from the device subnet to the TFTP server,
using the following command lines:
# config ip dhcp-relay
# create 10.0.0.1 10.1.1.2 mode dhcp state enable
# create 10.0.0.1 196.10.229.2 mode dhcp state enable
The create command has the form
where
address of the server that the DHCP frame should be forwarded to.
3 Save the configuration.
372 Novell ZENworks 7.3 Linux Management Administration Guide
Step 1
to
Step 5
again and specify the Proxy DHCP server IP address at
is the IP address of the gateway that serves the PXE device, and
agent
create agent server mode dhcp state enable
Step
3.
,
is the IP
server

Advertisement

Table of Contents
loading

This manual is also suitable for:

Zenworks linux management 7.3 ir2

Table of Contents