HBA latch
When this parameter is set to ON, the heater burnout alarm is held until either of the
following conditions is satisfied:
a The heater burnout set value is set to 0.0A".
Function
b The controller's power OFF is turned OFF then back ON again.
[
Comment
F Related article
4.4 How to Use the Heater Burnout Alarm (page 4 9)
F Related parameters
See
Control output assignment 1" Control output assignment 2" Auxiliary output
assignments 1" Auxiliary output assignments 2" (setup mode)
Remote SP enable
When this parameter is set to ON", the remote SP and local SP can be switched for
use. (That is, to the SP mode can be specified.) Also, the set point during SP ramp"
parameter is enabled at all times.
Function
When this parameter is set to OFF", only the local SP can be used. The set point dur
ing SP ramp is enabled only when the SP ramp function is enabled.
[
Comment
F Related article
4.3 How to Use the Remote SP (page 4 7)
F Relate parameters
See
Set point during SP ramp" (level 0 mode)
SP mode" (level 2 mode)
Setting Range
]: Enabled/[
]: Disabled
Setting Range
]: Enabled/[
]: Disabled
Option Mode
Conditions of Use
The HBA output function must be
assigned.
Default
[
]
Default
[
]
5–39