Upgrade a two-cabinet system with metal cable to Option 11C
553-3021-250
Standard 7.00
Figure 9
SDI Port 0
2
Log in to and perform a data dump on the existing system.
You must do this step to make sure you back up any changes made
after the last data dump. This step is a precautionary measure. If the
upgrade fails, you can revert to the earlier system.
a
Load Overlay program 43 (LD 43).
b
Enter command EDD.
c
Wait until the data dump finishes.
3
Load overlay program 22 to print the ISM parameters. Make a note
of the existing parameters.
a
Type SLT at the REQ prompt and press <CR> to print the ISM
parameters.
b
Make sure the ISM parameters are also on the existing software
cartridge.
4
Do one of the following to extract the customer data from the
existing system:
April 2000
SDI Port