Page 78 of 224
Upgrade a two-cabinet system with metal cable to Option 11C
553-3021-250
Standard 7.00
19
Install a fiber routing guide under slot 0 (Fbr Rx), as shown in
Figure 26 on page 70.
Install the fiber routing guide in the cable connector area below the
circuit cards. Fasten the router with the existing screws below the card
slot.
20
Connect all the cables that you labeled and disconnected from
the old cabinet in Step 14 on page 77.
Note: The connectors in the cabinet for cables going to the
cross-connect terminal are J1 to J10 (instead of J11 to J20 as in the
old expansion cabinet). Connect the labeled cables now as shown in
Table 2.
Table 2
Labeled cable connections
Label on cable
J11
J12
J13
J14
J15
J16
J17
J18
J19
J20
21
Route the fiber-optic cable from the main cabinet through the
cable entry area of the expansion cabinet.
22
Wear the antistatic wrist strap located in the expansion cabinet.
April 2000
Connect to connector
J1
J2
J3
J4
J5
J6
J7
J8
J9
J10

Advertisement