Assign TDS/DTR, XTD, and SDI functions
Procedure 16
Define SDI ports 1 and 2
1
Load overlay program 17 (LD 17).
2
Configure SDI ports 1 and 2 as shown in Table 23.
Table 23
LD 17 - Configure SDI ports 1 and 2.
Prompt
Response
REQ
CHG
TYPE
CFN
ADAN
NEW TTY X
CDNO
0
PORT
X
DES
aaa...a
BPS
150, 300, 600, 1200,
2400, (4800), 9600,
19200
BITL
5, 6, 7, (8)
STOP
(1), 1.5, 2
PARY
ODD, EVEN, (NONE)
ENL
(YES), NO
USER
BUG, SCH, MTC
. . .
—————————— End of Procedure ——————————
Option 11C and 11C Mini
Page 143 of 224
Comments
Change.
Configuration data block.
X=1
X=2
Card number 0.
X=1
X=2
AML port identification (can be
up to 16 alphanumeric
characters).
Bits per second data rate.
Data bit length.
Number of stop bits.
Parity.
Auto-enable SDI port.
Upgrade Procedures Guide