Assign TDS/DTR, XTD, and SDI functions
10
Configure SDI ports 1 and 2 on the SSC card using LD 17 (shown
in Table 10).
Refer to the SDI printout you got in Step 1 on page 132.
Table 10
LD 17 - Configure SDI ports 1 and 2.
Prompt
Response
REQ
CHG
TYPE
CFN
ADAN
NEW TTY X
CDNO
0
PORT
X
DES
aaa...a
BPS
150, 300, 600, 1200,
2400, (4800), 9600,
19200
BITL
5, 6, 7, (8)
STOP
(1), 1.5, 2
PARY
ODD, EVEN, (NONE)
ENL
(YES), NO
USER
BUG, SCH, MTC
. . .
11
Enable the SDI ports in LD 37.
Use the commands "ENL TTY 1" and "ENL TTY 2."
12
Enable the TDS/DTRs on the SSC card using LD 34.
Use the "ENLX 0" command.
Option 11C and 11C Mini
Page 135 of 224
Comments
Change.
Configuration data block.
X = 1
X = 2
Card number 0
X= 1
X = 2
AML port identification (can be
up to 16 alphanumeric
characters)
Bits per second data rate
Data bit length
Number of stop bits
Parity
Auto enable SDI port
Upgrade Procedures Guide