Nortel Meridian 1 Option 11C Upgrade Manual page 27

Hide thumbs Also See for Meridian 1 Option 11C:
Table of Contents

Advertisement

Upgrade a single-cabinet system to Option 11C
The following is a summary of the steps as described in the Option 11C
Planning and Installation Guide (553-3021-210) :
a
Enter the system time and date if the system prompts you. Skip
this step if the Software Installation Main Menu appears instead.
Note: The system time and date prompt appears when the Software
Installation Program detects a system year date that is not in the range
of 1995 to 2095.
b
Select the type of upgrade you plan to do.
• If using the Software Delivery (PCMCIA) card
i
Select System Upgrade from the Software Installation
Main Menu.
ii
Select "Option 11/11E to Option 11C" from the "Select
type of upgrade to be performed" menu.
• If you are using the Software Daughterboard, select "New
System Installation or Option 11/11E Upgrade - From Software
Daughterboard."
c
Select the feature set to be enabled.
Select the feature set from the "Select Feature Set You Wish to
Enable" menu.
Note: The items you select in steps c, d, f, g and h must match the one
provided with keycode data sheet.
d
Select feature package numbers to add (if any).
Enter the package numbers. Press <CR> twice to end package
selection.
e
Select the database source.
Select one of the following from the "Select Option 11/11E
Database Source" list:
• CCBR file. Select this option if you used the CCBR feature to
extract the customer database. This option accesses the Data
Transfer mode. To begin the data restoration and upgrading
process, enter <CR> when prompted.
• Option 11/11E Software Cartridge. Select this option if you are
using the Database Upgrade Tool to extract the customer
database from the existing software cartridge.
f
Select the ISM parameters.
Option 11C and 11C Mini
Page 27 of 224
Upgrade Procedures Guide

Advertisement

Table of Contents
loading

This manual is also suitable for:

Meridian 1 11c mini

Table of Contents