Page 42 of 224
Upgrade a two-cabinet system with metal cable to Option 11C
553-3021-250
Standard 7.00
13
Extract the customer database from the existing system.
Do one of the following:
— If you are using the CCBR feature, skip this step and go to Step
14.
— If you are using the Database Upgrade Tool, install the software
cartridge from the existing system to the Database Upgrade Tool.
a Remove the software cartridge from the existing NTAK01
CPU/Conf or NTBK45 System Core card.
b Connect the Option 11 or Option 11E software cartridge to the
connector on the Database Upgrade Tool.
c Make sure the software cartridge on the Database Upgrade
Tool faces towards the left. Then insert it in slot B of the
PCMCIA socket located in the faceplate of the NTDK20 SSC
card.
14
Install the NTBK48 three-port SDI cable to the SDI port.
Connect the TTY terminal to the connector on the NTBK48 cable
labeled "Port 0" (see Figure on page 43).
Note: This cable is used with the Option 11E system.
The TTY must connect to port 0 to access the Software Installation
Program.
April 2000