Summary of procedures

Remove the NTAK03 TDS/DTR card

553-3021-250
Standard 7.00
Assign TDS/DTR, XTD, and SDI functions
Move some of their functions to the NTDK20 SSC card.
Assign additional functions to the NTDK20 SSC card.
The following procedures are in this chapter. These procedures describe how
to change the tone and SDI functions to meet the different requirements of the
Option 11C.
Procedure 11 "Remove the NTAK03 TDS/DTR card" on page 132
Procedure 12 "Remove the NT5K20/48 XTD card" on page 136
Procedure 13 "Move TDS/DTR while keeping SDI ports" on page 138
Procedure 14 "Move SDI ports while keeping TDS/DTR" on page 140
Procedure 15 "Define TDS/DTR/XTD on the NTDK20 SSC" on
page 141
Procedure 16 "Define SDI ports 1 and 2" on page 143
Perform this procedure to remove the NTAK03 TDS/DTR card and use the
NTDK20 SSC card instead. Changing to the NTDK20 SSC card frees one
card slot in the main cabinet.
Note: Perform the steps below in the order indicated. The TDS must be
assigned to the SSC card in slot 0 before the DTR units are programmed.
In addition, the TDS/DTR card must be disabled before removing the
TDS from its card slot.
Procedure 11
Remove the NTAK03 TDS/DTR card
1
Print the existing SDI configuration in LD 22.
Use the PRT request and ADAN or PRT type (depending on software
release) to get a printout.
2
Disable the TDS/DTR card in LD 34.
Use the DISX N command where N is the card slot number of the
TDS/DTR card.
3
Disable SDI ports 1 and 2 in LD 37.
Use the DIS TTY N command, where N is 1 and 2 (the SDI port
number).
April 2000