Garmin Beechcraft 200 Series Cockpit Reference Manual page 226

Hide thumbs Also See for Beechcraft 200 Series:
Table of Contents

Advertisement

Annunciations & Alerts
Message
GDC2 MANIFEST – GDC2 software
mismatch, communication halted.
GDL59 CONFIG – GDL 59 config
error. Config service req'd.
GDL59 FAIL – GDL 59 has failed.
GDL59 MANIFEST – GDL59
software mismatch, communication
halted.
GDL59 RTR FAIL – The GDL 59
router has failed.
GDL59 SERVICE – GDL 59 needs
service. Return unit for repair.
GDL69 CONFIG – GDL 69 config
error. Config service req'd.
GDL69 FAIL – GDL 69 has failed.
GDL69 MANIFEST – GDL software
mismatch, communication halted.
GEA # [1, 2] INOP - CAL – Check
GEA rigging.
GEA # [1, 2] INOP - CNFG
– Check GEA software and
configuration.
GEA # [1, 2] INOP - COMM –
Check GEA config module connection.
GEA # [1, 2] INOP - INTRL – GEA
internal fault.
GEA # [1, 2] INOP - SENS – Check
GEA configuration.
GEA # [1, 2] INOP - TEMP –
Check GEA config module cooling.
GEA # [1, 2] INOP - VOLT –
Check GEA voltages.
GEA1 CONFIG – GEA1 config error.
Config service req'd.
202
Garmin G1000 NXi Cockpit Reference Guide for the Beechcraft 200/B200 Series
Comments
The GDC2 has incorrect software installed. The system should
be serviced
GDL 59 configuration settings do not match those of backup
configuration memory. The system should be serviced.
A failure has been detected in the GDL 59. The receiver is
unavailable. The system should be serviced.
The GDL 59 has incorrect software installed. The system should
be serviced.
A failure has been detected in the GDL 59 router. The system
should be serviced.
A failure has been detected in the GDL 59. The system should
be serviced.
GDL 69A SXM configuration settings do not match those of
backup configuration memory. The system should be serviced.
A failure has been detected in the GDL 69A SXM. The receiver
is unavailable. The system should be serviced
The GDL 69A SXM has incorrect software installed. The system
should be serviced.
There is a problem with the GEA rigging. Check the rigging.
There is a problem with the GEA software configuration. Check
the configuration. If the problem persists, the system should be
serviced.
There is a problem with the GEA config module connection.
Check the connection.
The GEA has an internal fault. The system should be serviced.
There is an error in the GEA configuration. Check the
configuration. If the problem persists, the system should be
serviced.
The GEA configuration module has insufficient cooling. If the
problem persists, the system should be serviced.
The GEA voltage is low. Check GEA voltages.
The GEA1 configuration settings do not match those of backup
configuration memory. The system should be serviced.
190-02040-01 Rev. B