v See Chapter 4, "Parts listing," on page 41 to determine which components are consumable, structural, or CRU
parts.
v If an action step is preceded by "(Trained technician only)," that step must be performed only by a trained
technician.
Error code
Description
405-905-xxx
Failed the LoopbackAtMACLayer test. A
failure was detected during the loopback test
at the MAC layer.
405-006-xxx
Passed the LoopbackAtPhysicallayer test.
405-906-xxx
Failed the LoopbackAtPhysicallayer test. A
failure was detected during the loopback test
at the physical layer.
405-006-xxx
Passed the LEDs test.
405-906-xxx
Failed the LEDs test. A failure was detected
while verifying operation of the status LEDs.
200
BladeCenter HS23E Type 8038 and 8039: Problem Determination and Service Guide
Action
1. Make sure that the component firmware or
driver is installed correctly, upgrade if necessary.
The installed firmware level can be found in the
DSA Diagnostic Event Log within the
Firmware/VPD section for this component. The
latest level firmware for this component can be
found in reference to this system type at
http://www.ibm.com/support/
docview.wss?uid=psg1MIGR-4JTS2T.
2. Rerun the test.
3. If the failure remains, refer to
http://www.ibm.com/support/
docview.wss?uid=psg1SERV-OPTN for the
corrective actions.
N/A
1. Make sure that the component firmware or
driver is installed correctly, upgrade if necessary.
The installed firmware level can be found in the
DSA Diagnostic Event Log within the
Firmware/VPD section for this component. The
latest level firmware for this component can be
found in reference to this system type at
http://www.ibm.com/support/
docview.wss?uid=psg1MIGR-4JTS2T.
2. Rerun the test.
3. If the failure remains, refer to
http://www.ibm.com/support/
docview.wss?uid=psg1SERV-OPTN for the
corrective actions.
N/A
1. Make sure that the component firmware or
driver is installed correctly, upgrade if necessary.
The installed firmware level can be found in the
DSA Diagnostic Event Log within the
Firmware/VPD section for this component. The
latest level firmware for this component can be
found in reference to this system type at
http://www.ibm.com/support/
docview.wss?uid=psg1MIGR-4JTS2T.
2. Rerun the test.
3. If the failure remains, refer to
http://www.ibm.com/support/
docview.wss?uid=psg1SERV-OPTN for the
corrective actions.