Lenovo BladeCenter HS23E Problem Determination And Service Manual page 178

Table of Contents

Advertisement

v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v See Chapter 4, "Parts listing," on page 41 to determine which components are consumable, structural, or CRU
parts.
v If an action step is preceded by "(Trained technician only)," that step must be performed only by a trained
technician.
Error Code Event ID
0x806f0607 806f0607-2584ffff
0x806f060d 806f060d-0400ffff
806f060d-0401ffff
0x806f070c 806f070c-2001ffff
806f070c-2002ffff
806f070c-2003ffff
806f070c-2004ffff
806f070c-2005ffff
806f070c-2006ffff
806f070c-2007ffff
806f070c-2008ffff
806f070c-2009ffff
806f070c-200affff
806f070c-200bffff
806f070c-200cffff
0x806f070c 806f070c-2581ffff
0x806f070c 806f070c-2581ffff
0x806f050d 806f070d-0400ffff
806f070d-0401ffff
164
BladeCenter HS23E Type 8038 and 8039: Problem Determination and Service Guide
Type
Error Message
Error
Processor (One of
CPUs) SM BIOS
uncorrectable CPU
complex error.
Error
Hard drive X (Drive
X) in failed array
[Note X=0,1]
Error
Memory device X
(DIMM X) memory
configuration error
[Note X=1-12]
Error
Memory (All
DIMMs)
configuration error.
Error
Memory (One of
the DIMMs)
configuration error.
Info
Hard drive X (Drive
X) rebuilt in
progress for Array
in system. [Note
X=0,1]
Action
1. Verify that you have the latest system
firmware (see "Updating firmware and
device drivers" on page 31).
2. (Trained technician only) If the error still
occurs, replace the microprocessors one at
a time (see "Removing a microprocessor
and heat sink" on page 81 and "Installing
a microprocessor and heat sink" on page
84).
3. (Trained technician only) If the error
continues, replace the system-board
assembly (see "Removing the
system-board assembly" on page 90 and
"Installing the system-board assembly"
on page 91).
1. Replace the storage drive (see "Removing
a hot-swap storage drive" on page 63 and
"Installing a hot-swap storage drive" on
page 64).
2. After the storage drive has been replaced,
rebuild the RAID array (see "Creating a
RAID array of hard disk drives" on page
35).
Make sure that the memory modules are
installed in the correct order and configured
correctly (see "Installing a memory module"
on page 66).
Make sure that the memory modules are
installed in the correct order and configured
correctly (see "Installing a memory module"
on page 66).
Make sure that the memory modules are
installed in the correct order and configured
correctly (see "Installing a memory module"
on page 66).
Information only; no action is required.

Advertisement

Table of Contents
loading

This manual is also suitable for: