Lenovo BladeCenter HS23E Problem Determination And Service Manual page 167

Table of Contents

Advertisement

v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v See Chapter 4, "Parts listing," on page 41 to determine which components are consumable, structural, or CRU
parts.
v If an action step is preceded by "(Trained technician only)," that step must be performed only by a trained
technician.
Error Code Event ID
0x806f0207 806f0207-2584ffff
0x806f020d 806f020d-0400ffff
806f020d-0401ffff
806f0223-2101ffff
Type
Error Message
Error
Processor X (One of
CPUs) has failed
with FRB1/BIST
condition. [Note:
X=1,2]
Hard drive X (Drive
Warning
X) predictive failure
[Note X=0,1]
Info
Powering off system
initiated by IPMI
Watchdog.
Action
1. Remove the blade server and ensure the
processors are installed correctly (see
"Installing a microprocessor and heat
sink" on page 84).
2. Verify that the system is running the
latest UEFI firmware (see "Updating
firmware and device drivers" on page
31).
3. Run the Setup utility (see "Using the
Setup utility" on page 18).
a. Make sure that both processors are
displayed by the system.
b. Load the default settings.
c. Go to the System Settings menu and
make sure the processor is enabled.
4. If the problem continues, replace the
processor (see "Removing a
microprocessor and heat sink" on page 81
and "Installing a microprocessor and heat
sink" on page 84).
5. (Trained technician only) If the error
continues, replace the system-board
assembly (see "Removing the
system-board assembly" on page 90 and
"Installing the system-board assembly"
on page 91).
Replace the storage drive (see "Removing a
hot-swap storage drive" on page 63 and
"Installing a hot-swap storage drive" on
page 64).
Information only; no action is required.
Chapter 6. Diagnostics
153