Lenovo BladeCenter HS23E Problem Determination And Service Manual page 152

Table of Contents

Advertisement

v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v See Chapter 4, "Parts listing," on page 41 to determine which components are consumable, structural, or CRU
parts.
v If an action step is preceded by "(Trained technician only)," that step must be performed only by a trained
technician.
Error Code Event ID
0x80070200 8007020f-2201ffff
0x80070200 8007020f-2582ffff
0x80070300 80070301-0301ffff
80070301-0302ffff
0x80070300 80070301-0701ffff
138
BladeCenter HS23E Type 8038 and 8039: Problem Determination and Service Guide
Type
Error Message
Error
FW/BIOS, firmware
progress (TXT ACM
Module) critical
Error
Group 2, PCI
express bus X,
Expansion Module
2-0, firmware
progress, no I/O
resources. [Note:
X=1, 2]
Error
Processor X,
temperature (CPU
X OverTemp)
non-recoverable
[Note: X=1, 2]
Error
System board,
temperature (Inlet
temp)
non-recoverable.
Action
This is a UEFI detected event. The UEFI
diagnostic code for this event can be found
in the logged IMM message text. Please refer
to "UEFI/POST error codes" on page 99 for
the appropriate actions.
This is a UEFI detected event. The UEFI
diagnostic code for this event can be found
in the logged IMM message text. Please refer
to "UEFI/POST error codes" on page 99 for
the appropriate actions.
1. Check the system event log for additional
temperature and fan information (see
"Event logs" on page 96).
2. Make sure that the room temperature is
within the operating specifications (see
"Features and specifications" on page 7).
3. Make sure that none of the air vents on
the BladeCenter unit and on the blade
server are blocked.
4. Make sure that all of the fans on the
BladeCenter unit are running.
5. Make sure that each bay of the
BladeCenter unit has either a device or a
filler installed.
6. Make sure that the blade server is not
missing any heat sinks, DIMMs, heat-sink
fillers, or DIMM fillers (see Chapter 4,
"Parts listing," on page 41).
7. Make sure that the CPU heat sink is
properly attached to the CPU (see
"Installing a microprocessor and heat
sink" on page 84).
1. Make sure that the room temperature is
within the operating specifications (see
"Features and specifications" on page 7).
2. Make sure that none of the air vents on
the BladeCenter unit and on the blade
server are blocked.
3. Make sure that all of the fans on the
BladeCenter unit are running.

Advertisement

Table of Contents
loading

This manual is also suitable for:

80388039

Table of Contents