v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v See Chapter 4, "Parts listing," on page 41 to determine which components are consumable, structural, or CRU
parts.
v If an action step is preceded by "(Trained technician only)," that step must be performed only by a trained
technician.
Error Code Event ID
0x80070100 80070114-2201ffff
0x80070200 80070201-0701ffff
0x80070200 80070201-1001ffff
80070201-1002ffff
80070201-1003ffff
80070201-1004ffff
Type
Error Message
Error
FW/BIOS, switch
(TPM Lock)
warning
Error
System board,
temperature (Inlet
temp) critical.
Error
Expansion Module,
temperature
(BPE4_X TMP)
critical [Note:
X=1-4]
Action
This is a UEFI detected event. The UEFI
diagnostic code for this event can be found
in the logged IMM message text. Please refer
to "UEFI/POST error codes" on page 99 for
the appropriate actions.
1. Make sure that the room temperature is
within the operating specifications (see
"Features and specifications" on page 7).
2. Make sure that none of the air vents on
the BladeCenter unit and on the blade
server are blocked.
3. Make sure that all of the fans on the
BladeCenter unit are running.
4. Make sure the air baffle and the fan
fillers are installed correctly.
1. Check the IBM support website for an
applicable retain tip or firmware update
that applies to this temperature error.
2. Make sure that the room temperature is
within the operating specifications (see
"Features and specifications" on page 7).
3. Make sure that none of the air vents on
the BladeCenter unit and on the blade
server are blocked.
4. Make sure that all of the fans on the
BladeCenter unit are running.
5. Make sure that each bay of the
BladeCenter unit has either a device or a
filler installed.
6. Make sure that the blade server is not
missing any heat sinks, DIMMs, heat-sink
fillers, or DIMM fillers (see Chapter 4,
"Parts listing," on page 41).
7. View the event logs provided by the
advanced management module for your
BladeCenter unit and resolve any related
errors that might be displayed.
8. Clear the CMOS data by removing the
system battery for 30 seconds (see
"Removing the battery" on page 61 and
"Installing the battery" on page 62).
9. Make sure that the heat sink is properly
attached to the microprocessor (see
"Installing a microprocessor and heat
sink" on page 84).
Chapter 6. Diagnostics
135